Where you are: Home pageYear 2018Issue (128) → Article:
AAA     ENG | POL

Physico-Mechanical Performance Evaluation of Large Pore Synthetic Meshes with Different Textile Structures for Hernia Repair Applications

Research and development

Authors:

  • Liu Pengbi
    College of Textiles, Dong Hua University, Shanghai, P. R. China
  • Shao Hong (j/w)
  • Chen Nan-Liang (j/w)
  • Chen Nan-Liang
    Ministry of Education, Engineering Research Center of Technical Textiles, Dong Hua University, Shanghai, P. R. China
  • Jiang Jin-Hua
    College of Textiles, Dong Hua University, Shanghai, P. R. China
  • Jiang Jin-Hua
    Ministry of Education, Engineering Research Center of Technical Textiles, Dong Hua University, Shanghai, P. R. China

Nr DOI: 10.5604/01.3001.0011.5743

Download... PDF
Full text
Download... PDF
references

Abstract:

This paper studied the relationship between the textile structure of warp knitted hernia repair meshes and their physico-mechanical propertiesto solve the problem of  hernia patch application evaluation and clear the mechanism of hernia patch structure-performance for  clinical application.     Six different prototypes of large pore meshes were fabricated, including four kinds of meshes with different pore shapes: H (hexagonal), D (diamond), R (round) and P (pentagonal); and two kinds of meshes with inlays: HL (hexagonal with inlays) and DL (diamond with inlays), using the same medical grade polypropylene monofilament. All meshes were designed with the same walewise density and coursewise density. Then the influence of other structural parameters on the physico-mechanical properties of the meshes was analysed.     The physico-mechanical properties  of these meshes tested meet the requirements of hernia repair, except mesh DL, whose tear resistance strength (12.93±2.44 N in the transverse direction) was not enough. Mesh R and P demonstrated less anisotropy, and they exhibited similar physico-mechanical properties. These four kinds of meshes without inlays demonstrated similar ball burst strength properties, but mesh HL and DL exhibited better ball burst strength than the others. All in all, uniform structures are expected to result in less anisotropy, and meshes with inlays, to some extent, possess higher mechanical properties. And the ratio of open loop number to closed loop number in a repetition of weave of fabric has marked effect on the physico-mechanical properties. Thus we can meet the demands of specific patients and particular repair sites by designing various meshes with appropriate textile structures.

Tags:

hernia repair, large-pore meshes, physico-mechanical properties, warp knitted meshes, pore shape, meshes with inlays.

Citation:

Liu P, Shao H, Chen N, Jiang J. Physico-Mechanical Performance Evaluation of Large Pore Synthetic Meshes with Different Textile Structures for Hernia Repair Applications. FIBRES & TEXTILES in Eastern Europe 2018; 26, 2(128): 79-86. DOI: 10.5604/01.3001.0011.5743

Published in issue no 2 (128) / 2018, pages 79–86.

CONTACT:

FIBRES & TEXTILES
in Eastern Europe
ul. Skłodowskiej-Curie 19/27,
90-570 Łódź, Poland
e-mail: infor@lit.lukasiewicz.gov.pl
ftee@lit.lukasiewicz.gov.pl
Events:

EDITORIAL OFFICE
FIBRES & TEXTILES in Eastern Europe 19/27 M. Skłodowskiej-Curie Str., 90-570 Łódź, Poland e-mail: infor@lit.lukasiewicz.gov.pl; ftee@lit.lukasiewicz.gov.pl

EDITORIAL DEPARTMENT
Editor-in-Chief Dariusz Wawro, Head of Editorial Office Janusz Kazimierczak, Text Editor Geoffrey Large, Assistant Editor Anna WahlProduction Łukasiewicz-ŁIT

facebook